HomeMy WebLinkAboutR-1994-158RESOLUTTON NO. 158-94
A RESOLUTION OF THE CITY OF DANIA, FLORIDA, APPROVING THE
PURCHASE OF SIX (6) LIFT STATION DATALOGGERS MANUFACTUREDBY MONITORING CONTROL SYSTEMS CORP., THE SOLE
MANUFACTURER, FROM THE DISTRIBUTOR, COMPLETE CONTROLS,
FOR THE SUM OF TWELVE THOUSAND ONE HUNDREO & NO/IOO.OO
DOLLARS ($12,100.00); AND PROVIDING FOR AN EFFECTIVE DATE.
BE IT RESOLVED BY THE CITY COMMISSION OF THE CIry OF DANIA, FLORIDA:
Section 1 . That the purchase of six (6) Lift Station Dataloggers (monitors) from
Complete Controls, 8124 Joyce Lane, Lakeland, Florida, 33809, the distributor for Monitoring
Control Systems Corp., the sole manufacturer of said equipment, for the sum of Twelve
Thousand, One Hundred and no/100 Dollars ($12,100.00) as set forth in letter from Complete
Controls attached hereto and made a part hereof as Exhibit "A', be and the same is hereby
authorized and approved.
Section 2. That the city manager be and he is hereby authorized to pay from the
sewer fund account to Complete Controls, the sum of Twelve Thousand, One Hundred and
No/100 dollars ($12,100.00) upon delivery of said equipment to the city.
Section 3. That all resolutions or parts of resolutions in conflict herewith be and the
same are hereby repealed to the extent of such conflict.
Section 4. That this resolution shall be in force and take effect immediately upon its
passage and adoption.
PASSED and ADOPTED on this 22 day of
ATTEST:
Nove mbe t1g
Mayor - Comm loner
City Clerk - Auditor
APPROVED AS TO FORM & CORRECTNESS
4.,-t r. z;f/,By:
Frank C. Adler, City Attorney
4/o-J,-,/ h""./'L'Z;-
Resolution No. 15 B- 94
COMPLETE, CONTROLS
l:
8124 Joyce Lane
Lakeland, Florida 33809
(813) 853-1 167
Fax (813) 858-1 927
November 8, 1994
Mr. Bud Palm
Ut i 1i.t ies DirectorCity of Dania100 west Beach BIvd.Dania, FL
33004
Quotation No: 416 0
Bud. Thank you for your interest in the MCSC IVOLUCALC" lift stationmonitoring system, The followrng quotation covers the cost of thestandard *DIN untt w].th power supply and startup assistance. Sincethere is goinq to be a price lncrease at the start of the year, I haveincluded both 1994 and 1995 prrcing. if you order at least half ofthe units you need before the end of December, I will hold the 1994pfice until March 1, L995. We quote as follows:
Each: Monitorinq Controls Systems Inc. I'VOLUCALC" mode]' D/PSRlift station dataLogqer. iDIN enclosure to be placed inside astandard pump station control panei-. Price includes a standard
L20vac/72vdc power supply. AI1 terminaf connections are via rearterminal panel. Logger is programmable and logs 14000 events. Thebelow price inc.Ludes the VOLUCALC PC software which will be upgradedfor free as nev, edi-ti-ons are available.
1994 Price each: $1950 .00
1995 Price each: $2038.00
Startup service is avail-able at $49.00/HR or $400/day
Note: The unit is downloadeC via standard computer cable connectioneither throuqh a DB-g connectron on the back of the unit or through amini stereo type pluq on the front of the unit. A11 communication is
RS-232.
Terms: 1810 , Net 30 FoB: Charlotte, Nc Delivery: 3-4 weeks
Note: If you need several sources to receive a competitive bid, Thefactory would be glad to quote you aLso. Their address, telephone,and contact are: MCSC. Inc. PO Box 580 Indian Trail, NC 28079.
Telephone : (7041821-6771 Fax: ( 7041821-6466. Contact: Ben Beaudoin.
Regards,
R Thn pps
iXHIBIT .,A"
V0"JICALC
Tothe improve pumping station management,
VOLUCALC will plovide instant data on:
PUMPING .G-qTION
MONITORINHYSTEM
- Cumulative volume
- Pump operating time
- Pump starts
- Low and high levels
- Power tailures
Simple and inexpensive, the VOLUCALCrecords each event that occurs in thepumping station for a month (up to 10,000events) and can transler this data to acomouier usino ils RS232 or its ootionalbuiltlin modem- . The PC/DOS s<iftware
supplied with the voLUcALc wall give you:
- The highest level ol accuracy
- Station settings auto.update
- Communication soflware
- Pump capacity lor each combination
- lnllow calculated trom different algorithms
- Reports (summary, graph, alerm, settings)
- Change of settings and recalculation
The VOLUCALC is so simple to operate, theoroorammino information tits on a businessbariL The pc/Dos software is extremelvuser-lriendly and powerlul The operato-r
may never have to open the user manual.
The VOLUCALC calculates the volume basedon preset pump capacities for each possible
combinalions and time.
An accurate inflow is needed to properly calcu-
late data like volume and pump capacilies. The
PCIDOS software uses the most accurate
algorithm to find the exact inflow at any time.
That algorithm is related to the previous, pre-
sent and luture events to the one calculated. lt
automaticallv switches between volume/lime
and pump's'capacity. Sometimes the sottware
will compute several days of data then come
back to compute a second time a pump cycle
because more accurale values were found at a
later time.-.-More than 18 monlhs o, development on the
algorithm alone were necessary to achieve this
level of accuracy.
Display:
Keyboard:
lnputs:
Outputs:
Units:
Volume:
Pump timers:
Pump starts:
Pump capacity:
Events:
Battery backup:
The VOLUCALC is connected in parallel to the
pump starters and the level switches or in seriallor an analoo level device like a oressure or
ultrasonic tra-nsducer. lt should noi take more
than 15 mrnutes to connect it il you know your
control panel.
For a temporary and fast installation, connect
the VOLUCALCTS power supply, the neulral, thepumps and levels wire usrng afligator clips.
AACK
Liquid Crystal 2x16
4 keys
8 digital, I analog, RS-232
2 digital (open collector)
2 analog 4-20mA, R5-232
G,MG,M3,G/m, MG/h, Us
999,999,999
HH:MM:SS, HH.00
999,999,999
999,999,999
10,000
'10 years (estimate)
SPECIFICATIONS
12 VDC, 5VA, External power supply
3.75" x 3.75'x 6" (95mm x 95mm x 152 mm)
One year, parts and labor
lvlodem, PCMCIA memory card, Power supply,
Key lock clear plastic splash proof cover-":;***;ffi;;;;;.
., SYSTEMS CORPORATION
l8i! Lrval, P.O. Bor 16{,Bromptonvlllc, OCCanada JoB 1H0
Ph. t8ull 668.3862Fax: (819, 646-s096
.nffio
-
li-fif;H'fil:fff:H:l
EASY INSTALLATION
- Easy installalion & operation
- lnerpensive & accurate
- Data logging & Gommunication
- Powerlul DOS software
ACCURACY
POWER
DIMENSIONS
WARRANTY
OPTIONS
. divirion ol BHF BESEARCH IITD.
VOflCALC PUMPING S ITION
MONITORING-ISYSTEM
FEATURES
1 Backlit alphanumeric display for easv to
read and easy to understand data
2 Optional key lock clear ptastic splash proot
cover to prevent unauthorized use.
3 Membrane that protects display and
keyboard against dust and dirt
4 Front RS232 serial port for fast and easy
access
5 Future optional PCMCIA memory card
6 User upgradable internal software possible
using the _tree PC/DOS software 3upplied
with the VOLUCALC
port for permanent7 Rear 85232 serial
installation
o @@ I
o
10
Phone jack ior optional built-in modem
Pluggable terminal blocks for fast servicinoof the instrument without disconnecting an!wires
External power supply gives us a choice of
electrical noise reduction characteristics andquality according to your pumping station
control panel
2 analog outputs proportional to outflow lor
existing telemetry system, sampler or chart
recorder
2 digital output open collector for alarm ortelemetry
I digital inputs: 3 pumps, 5 levels
8 analog inputs: Level transducer, (future
use)
15 Easy to understand terminal code
to reduce errors during installation
11
12
13
14
1 6 Small package for installation for
new or upgrade to existing control
panel
17 Standard size DIN enclosure soelectrician can do a clean
installation
18 Screw type bracket
servrcrng
for easy
sr.EEc(fuu-tr.di
12/20 18:
VOLUME
MG
432345
Nlmfril,1 ffif'E{ruE.ffi*
183 Lavsl. P.O, Bor 160Bromotonville. OCCanide JoE'lHoPh. (8(x)) 668-3852Fax: (Ei9, 846-3096
@
MONITORING COI{TROL
SYSTEMS COBPORATION
a division ol BHF RESEARGH LTD.
v0.ucALc PUMPING S' \TION
MONITORING SFTWARE
The Volucalc lift pumping station software
produces information like: lnrlow (mrn., max.,
mean), Outflow (min., max., mean per pump
and combination), Volume, Pumps (number
and time ot operation lor each pump
combination), Alarms (high
and
and
low level, power failluro, starlingand ending time), Summary
Graphic and Alarm reports (tor
the time and flow scale wanted),
Settings report. Moniloring
Conlrol Systems Corp. has
created the most accurale
algorythm used lo calculate llowin pumping stations. The data
can be transterred lrom the
Volucalc's internal memory usingits serial porl or its oplional
modem. Slation settings can be
change at any time. The Volucalc sottware
with its communication functions is the answer
lor the manager looking for a tool that is
power{ul and easy to use.
tDl..: f.!ru*y t r
MONITORING CONTROL
SYSTEMS CORPORATION. diYi.ion ol BHF RESEARCH LTD.
SYSIEM
BEOUIFE.
MENTS:
MS-OOS
u3i.9 80l€6
lll:! Lav8l. P.O. Box 160Bromplonvilla, OCCenede JOB IHOPh. 18001 668-3862Fax: 16191 64&3096
Irurr. tt..ts Itr r.7r.. curr. rtr IIl',':r' Il.ll:r. I
L!-. 1.
I
I
I
I
III