Loading...
HomeMy WebLinkAboutR-2010-112 Indigo Hotel Site Plan RESOLUTION NO. 2010-112 A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF DANIA BEACH, FLORIDA, APPROVING THE SITE PLAN REQUEST (SP-31-10) SUBMITTED BY SAM JAZAYRI, REPRESENTATIVE FOR DOWNTOWN DANIA BEACH DEVELOPMENT, LLC, AND THE PROPERTY OWNER, GRIFFIN RANCHES DEVELOPMENT LLC,FOR PROPERTY LOCATED AT 48 SOUTH FEDERAL HIGHWAY IN THE CITY OF DANIA BEACH, FLORIDA; PROVIDING FOR CONFLICTS; FURTHER,PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, Section 8.4, Article 1, Chapter 8, of the Code of Ordinances of the City of Dania Beach, Florida, states that a site plan is required as a condition to the issuance of a building permit; and WHEREAS,Sam Jazayri, representative for Downtown Dania Beach Development, LLC, and the property owner,Griffin Ranches Development LLC,is requesting site plan approval to allow construction of a 7 story, 120 room hotel in the City of Dania Beach; and WHEREAS,the Planning and Zoning Board on July 21, 2010, recommended that the City Commission grant the site plan request(SP-31-10),based upon the criteria set forth in Section 8.4, Article 1, Chapter 8, of the Code of Ordinances of the City of Dania Beach; NOW, THEREFORE, BE IT RESOLVED BY THE CITY COMMISSION OF THE CITY OF DANIA BEACH, FLORIDA: Section 1. That that certain application (SP-31-10) for site plan approval, a copy of which is attached and made a part of this Resolution as Exhibit"A" is approved with the following design variations and site plan conditions: DESIGN VARIATIONS: 1. To provide 0' setback on south property line; code requires a 10' setback, per Section 21.14(a) (2). 2. To allow a 2' setback from Federal Highway; code requires a 25' setback, per Section 21.14(a)(1). 3. To allow a 0' building recess;code requires a 15' recess on street frontage(east and west)and a 30'recess on sides(north and south), per Section 21.14(b)(2). 4. Provide 149 parking spaces, code requires 159, per Section 21.20. CONDITIONS: 5. Provide dimensions of loading/service delivery space on site plan,must provide 14'vertical clearance and a minimum 12' X 25"dimensions(Planning Division). 6. Identify lot coverage, maximum permitted in 90%(Planning Division). 7. Must provide 6 foot wide sidewalk on SW 1 Street. Revise accordingly(Planning Division). 8. Relocate bench and trash receptacle adjacent to public sidewalk(Planning Division). 9. Revise parking calculations on cover sheet to identify 120 rooms at 1.1 space per room and meeting space, restaurant and bar at 1 space per 150 s.f. for a total of 159 parking spaces required (Planning Division). 10. Add the 10 parallel spaces to the total parking provided in the parking calculations(Planning Division). 11. Sheet L-1 shows I tree in landscaped island adjacent to SW 1 Avenue, Sheet A2.01 shows 2 trees. Revise accordingly(Planning Division). 12. All curbing must be type "D"or"F". Identify on site plan and provide detail (Planning Division). 13. Provide approval from FDOT for new curb cut on Federal Highway(Planning Division). 14. Provide copy of plat(Planning Division). 15. Sheet L-1 remove notes referencing Miami Springs(Landscape Consultant). 16. Sheet L-2 add note requiring pre-construction meeting with City landscape consultant Michael McCoy, contact at 954-643-0423 at least 48 hours prior(Landscape Consultant). 17. Sheet L-I remove landscape calculations table,replace with"Landscaping requirements per direction of CRA Director. Any modifications to species, size or locations require prior approval by the City" (Landscape Consultant). 18. Provide a Hydrant Flow Test to determine the available water supply to this project. This test must be performed by a qualified company of the builder's choice. In addition,the static pressure at the water main shall be determined by a recorded method(i.e.water wheel)for a minimum twenty-four(24)hour period. The actual flow test must be witnessed by, and recorded data sent to the City of Dania Beach Fire Prevention Bureau in any area where water is being supplied by the City of Dania Beach Public Services (Fire Marshal). If the water is being supplied by Broward County, the entire hydrant flow test is to be performed by Broward County O.E.S. Please contact the City of Dania Beach Fire Prevention Bureau at (954) 893- 5060 for determination of where the water is being supplied from (Fire Marshal). 19. Identify the Needed Fire Flow Requirements for all buildings/structures. Fire Flow calculations shall be prepared by a professional engineer currently licensed in the State of Florida for each newly constructed building.The Needed Fire Flow Requirement must be in accordance with N.F.P.A. 1 (2006 Ed.),Annex H or The Guide for Determination of Needed Fire Flow, latest edition,as published by the Insurance Service Office(ISO). All calculations must be demonstrated and provided(Fire Marshal). 20. The Hydrant Flow Test must be in accordance with the Broward County Amendments(2005 Ed.)to the Florida Fire Prevention Code (2007 Ed.)as follows: Broward County Amendments to the Florida Fire Prevention Code(2005 Amendments) F-22—Automatic Sprinklers Required F-22.1 — Fire flow testing of the Water Supply for Automatic Fire Protection Systems (AFPS) and Automatic Standpipe systems (ASS) using water as an extinguishing agent for new buildings and structures and existing buildings and structures where the AFPS and ASS are altered by more than seventy-five percent(75%)of their value shall be as follows: a. Fire flow test of the water supply for AFPS and ASS shall be in accordance with NFPA 291, Recommended Practice for Fire Flow Testing and Marking of Hydrants,Florida Administrative Code (FAC) 69A-60.005(2). b.Design for AFPS and/or ASS shall be calculated using a maximum of fifty(50)pounds per square inch (psi)as the static pressure to allow for drought conditions. Example: If the results of a Fire Flow Test have a static pressure of eighty(80)psi,a residual pressure of seventy-two (72) psi and a flow of 1,300 gallons per minute (gpm), the design water supply for an AFPS and/or ASS would be a static pressure of fifty(50)psi, a residual pressure of forty-two(42)psi and a flow of 1,300 gpm. c.Design for AFPS and/or ASS at or below a static pressure of 55.56 PSI shall be calculated using a ten(10)percent reduction in the static pressure from the fire flow test to allow for drought conditions. Example: If the results of a Fire Flow Test have a static pressure of fifty-three (53) psi, a residual pressure of forty-five(45)psi and a flow of 925 gpm,the design water supply for an AFPS and/or ASS would be a static pressure of 47.70 psi,a residual pressure of 39.70 psi and 2 RESOLUTION#2010-112 a flow of 925 gpm. d. Design for AFPS and/or ASS for the residual pressure shall be equal to the difference between the static and residual pressures as obtained from the fire flow test to allow for drought conditions. Example: If the result of a Fire Flow Test has a static pressure of eighty-five (85) psi, a residual pressure of seventy-seven(77)psi,the difference in the static and residual pressures would be eight(8)psi which would be utilized for the drought condition water supply design criteria. If the result of a Fire Flow Test has a static pressure of forty(40)psi,the difference in the static and residual pressures would be ten(10)psi which would be utilized for the drought condition water supply design criteria. e. Design of the water flow for the AFPS and/or ASS shall be the same as that obtained from the fire flow test. f. The residual pressure at the required water flow at the connection to the water main for an AFPS and/or Ass shall not be less than 20 psi. g. The static pressure at the water main shall be determined by a recorded method for a minimum twenty-four(24)hour period(Fire Marshal). 21. Fire Flow Test Data shall not be more than one (1) year prior to the plans, hydraulic calculation and submittals for the AFPS and/or ASS being submitted to the Authority(ies)Having Jurisdiction(AHJ's)for their review and acceptance. The results of the fire flow test shall be provided to the AHJ at the time of the submittal of the plans, hydraulic calculations and submittals for the water based AFPS and/or ASS (Fire Marshal). 22. Provide a note on the plans for vertical clearance requirements for apparatus:Vertical clearances of 14 ft. minimum are required by AHJ (Fire Marshal). 23. Provide"no parking"signage in accordance with the Requirements listed below in areas as indicated on the attached Plans. "NO PARKING"signage, painted curbs and/or fire lane striping required For fire lanes,Fire Department access roads and in front of Fire Department connections Fire Lanes,Access Roads and the areas in front of the Fire Department connections,shall be designated by yellow painting,striping, or markings on the curbs and roadways. 1. Provide a curb detail note to indicate that all curbs are to be painted yellow. 2. All pavement markings shall be of thermoplastic paint. 3. Demonstrate that these areas are to be marked with freestanding signs with the wording, "NO PARKING FIRE LANE BY ORDER OF THE FIRE DEPARTMENT"or similar wording. 4. Such signs shall be 12 inches by 18 inches with a white background and red letters. 5. These signs shall be a maximum of seven feet in height from the roadway to the bottom of the sign. These signs shall be within sight of the traffic flow and be a maximum of 60 feet apart. [1:18.2.3.5] (Fire Marshal) 24. Provide impact protection for Fire Department Connection(fdc)and backflow preventer.Provide a detail on the plan in accordance with the following: Provide bollards consisting of three inch steel pipe buried at three feet deep, with three feet of height above ground level and spaced three feet apart,these bollards are to be filled with concrete and capped are acceptable. [24:7.3.5] [24:7.3.61 [13:8.15.1.3.2] (Fire Marshal) 25. Provide a detail for the signage for Fire Department connections in accordance with the following: 1. The FDC must be identified as to the building(complete address)or portion of the building it serves. Provide a permanent tactile sign at the FDC to meet the above requirement. [14:6.3.5.3] 2. Each Fire Department connection shall be designated by a sign having raised letters, at least 1 inch in height, cast on a plate or fitting that reads "STANDPIPE", "STANDPIPE AND AUTOSPKR" or "AUTOSPKR AND STANDPIPE". [14:6.3.5.2] 3.A sign also shall indicate the pressure required at the inlets to deliver the system demand. [14:6.3.5.2.21 (Fire Marshal) 26. Identify and demonstrate the locations of all surrounding fire hydrants(Fire Marshal). 3 RESOLUTION#2010-112 27. Demonstrate the locations of standpipes and Fire Department Connection's on the plans(to be located in the stairwells)(Fire Marshal). 28. Please re-locate the fire command room as indicated on the attached plans.If this location is not possible, please consult the Fire Marshal for alternatives. 29. Additional comments will be made by the City Engineer that must be addressed prior to issuance of a building permit(Planning Division). It is further noted that the original site plan is maintained in the office of the Community Development Department of the City of Dania Beach. Section 2. That based upon the criteria set forth in Section 8-4(p),Article 1,Chapter 8,of the Code of Ordinances of the City of Dania Beach,all site plan approvals shall automatically expire and become null and void unless the applicant files a complete building permit application and submits complete contractor drawings within twelve (12) months from the date of approval of the site plan by the City Commission,and the applicant obtains a building permit(including payment of all fees) within eighteen (18) months of the date of this Resolution. Section 3. That all resolutions or parts of resolutions in conflict with this Resolution are repealed to the extent of such conflict. Section 4. That this Resolution shall be in force and take effect immediately upon its passage and adoption. PASSED AND ADOPTED on July 27, 2010. ATTEST: o�aS F]Rsr pp/ v X17i 4- LOUISE STILSON, CMC C. K. McELYffA CITY CLERK ^ap° MAYOR—COMMISSIONER APPROVED AS O Ft AND CORRECTNESS: THO AS J. Al O CITY ATTORNEY 4 RESOLUTION #2010-112 City of Dania Beach,Florida Deparbeenat of Commualtr Development planning and Zoning Divislon (9")924-GWS X3643 Gensmi Development Application ❑ Administrative Variance ❑ Assignment of 14WRoserve Uaft❑ / ib Land use A nendmenc ❑ Plat ' 1❑ Not Delegation Request ❑ Rezoning Data Roca: D Ol emePtion petition Re.: ❑ TraNkaey waiver ❑ Variance VA- 33- I O ❑ Roadvisy Vacation ❑ otter: THIS APPLICATION WILL NOT RE ACCEPTED UNTIL IT IS COMPLETE AND SUBMITTED WITH ALL NECESARRY DOCUMENTS. Refer to the application type at the top of this form and "Required Doenenardation`checklist to determine the supplemental documents required with each application. For after the fact applications, the responsible contractor of record sW be present at the board hearing. Their failure to attend may impact upon the disposition of your application. As always,the applicant or their authorized legal agent must be present at all meetings. All projects must also obtain a building g permit from the City'k Building Department Location Address: 4 ;! LOt(s): % jf; Block: Subdivision: Recorded Plat Name: /"/q f' _ %71, Folio Number(sj <• Legal Desalption: Appiica RarrylegalRepreseNatve(drde WO) { kJ:'J4}ir,=u'J�isfvl?,/ � cfrCiivt�fLtti!%i! < i Adhessofapplkam: 51 fr. ill, i C/r r-l.t/iN/ w[_ act(✓, fG/� r!,xC' Bus#xw Telephone:� Home: Fax: Name of Property Owner: Address of Property owner r'1%rL z" Business Telephorw T:i- &1`14- Home: _ Fax: r.%xt f]cpfamtionofRaquest: l!/JiL[ri!'11 /='C7 �,'�Ai}'j._ :f TF?7/(7 OA /1 For Atsb Ante P VA*PoP sod PAmt Name for VWAWCes PAmw attach C iforip SYsAarreint as per ArM*10.13 of04PW 2B,ZoWM Code. Prop.Net AcreW. �h:f 1 Gros Acmage- i- r? ' Prop.Squam Footage: -- Existing Use: i:7 Proposed Use: ! F71 Is property owned individually,by a corporation,or a joint venture? rundefstafW i�site plan and variance approval auWmatirally eupires within 12 months Of City issiolt approval,pursuant to Ordinaries No.2005-040. 10 AppiicartJOwner signature Print Name Date APPLICANT,CONSULTANT,OR LEGAL REPRESENTATIVE NOTARIZED SIGNATURE Swom to and subscribed before me Appaanr/ConsultarrOZepmsentadve: This 2 day of2o/ (Jr�<� Signature: Sign Name of Notary, NW (Print Name) $tateaf(�'�OR1.� ) J*w%cyr]-CRG(nij'Q i Jc`c�c-s� fl n71a CRC yo 5, Print Name of Notary Street Address,Qty,State and Zip Code 1�RESAANNGROS 0-y— 95 ? 'L +t Comm scion DD 735543 Telephone No.&fax No. Exp res December 26,2011 m�au m�,nq w inu.a roorraau INDIVIDUAL OWNER NOTARIZED SIGNATURE: This Is to certify that I am the fee simple owner of subject lands described above and that I have authorized (Applicant/Ms lt"Represeitaave) to make and file the aforesaid application. Sworn to and subscribed before im Owner. TM_day of 20 Signature: Date: Sign Name of Notary Pubik (Print Name) State Of( ) Print Name of Notary Street Address,City,State and Zip Code ComrrrBskm Eq*m: Seal: Telephone No.&Fare No. j : CORPORATION NOTARIZED SXMTORE: This Is to certify that the below referenced corpmatfon Is the owner of subject lands described above and that I, as a duty authorhed officer, have authortmd (gppkant/CorgdtanyRepresentay e) make and file the aforesaid application. Sworn to and subscribed before me Corporation Name: Th& day of `� ( 20 tO Date 7 Zz he (Print Name) Sign Name of Notary Public (Print Title) State of(6_ // qQ� / t CL H- tlF di .L (°. d, _S' �©0/ Print Name of Notary Sbeet Address,Cily,State and Zip Code 9Fr/-//,c'� 9s y� 9G 5<-7 " y TH RESA Telephone No.&Fax No. j,. Commission DO 735643 Expires December 20,20i 1 e.naem*wwnmwwiPio 7CINT VENTURE FPO ATNERSIQP NOTARIZED SIGNATURE: This is to certify that the below referenced that the duty aunt mend persons are the owners of subject lands described above and that an partners have auftrved (AppscantjamwtangRepreaentauw) m make and file the aforesaid application. Sworn to and subscribed before me This_day of ZO Signature: Date: (Print Name)** Sign Name of Notary Public State of( ) Print Name of Notary Street Address,City,State and Zip Code Commission Expires:_ Seal: Telephone No.&Fax No. **Each pwbwr most sign. Atbch dupliewim sheats as requited.