Loading...
HomeMy WebLinkAboutR-2025-044 R-SP-073-18 Broward Gardens Site PlanRESOLUTION NO. 2025-044 A RESOLUTION OF THE CITY COMMISSION OF THE CITY OF DANIA BEACH, FLORIDA, APPROVING THE SITE PLAN (SP-073-18) SUBMITTED BY APPLICANT, R, ROMA HOLDINGS, LLC, A FLORIDA LIMITED LIABILITY COMPANY, FOR PROPERTIES LOCATED AT 4432-4440 SW 52ND STREET IN THE CITY OF DANIA BEACH, FLORIDA; PROVIDING FOR CONFLICTS; FURTHER, PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, Chapter 28, “Land Development Code” (the “LDC”), Part 6, entitled “Development Review Procedures and Requirements,” Article 635, entitled “Site Plans” of the City Code of Ordinances (the “City Code”) provides that Site Plan approval is required as a condition to the issuance of a building permit; and WHEREAS, R. Roma Holdings LLC, a Florida limited liability company (the “Applicant”) is requesting a Site Plan Approval (SP-073-18) for a four (4) single-family home development on the property legally described in Exhibit “A”, which is made a part of and incorporated into this Resolution by this reference, and WHEREAS, the Applicant is requesting approval of the proposed Site Plan (SP-073-18) to permit the future development of the subject property pursuant to and consistent with the attached site plan provided as Exhibit "B", a copy of which is made a part of and incorporated into this resolution: and WHEREAS, the Applicant has provided sufficient justification demonstrating compliance with the approval criteria to meet the requirements of the Code; and WHEREAS, the City’s Staff Report analyzes the applicant’s request based on the criteria and supports the Applicant’s request and is incorporated by reference herein as the City’s findings WHEREAS, the City Commission conducted a duly noticed public hearing in accordance with Article 610 of the LDC; and WHEREAS, the City Commission finds that the approval of the Site Plan (SP-073-18) is consistent with the City’s Land Development Code and Comprehensive Plan and will protect the public health. safety, and welfare of the residents of the City, and furthers the purpose, goals, objectives, and policies of the Comprehensive Plan. NOW, THEREFORE, BE IT RESOLVED BY THE CITY COMMISSION OF THE CITY OF DANIA BEACH, FLORIDA: 2 RESOLUTION #2025-044 Section 1. That the foregoing “WHEREAS” clauses are ratified and confirmed as being true and correct, and they are made a part of and incorporated into this Resolution by this reference. Section 2. That pursuant to Chapter 28 “Land Development Code,” Part 6 “Development Review Procedures and Requirements,” Article 635 “Site Plans,” the following Site Plan (SP-073-18), attached as Exhibit “B,” which is made a part of and incorporated into this Resolution by this reference, is approved. Section 3. That the approval granted by this Resolution is subject to the Applicant's compliance with the following conditions: 1. Revise the elevation of 5.61 ft, NAVD, left of the CB#2 to be greater than elevation 6.0 feet, NAVD in the drainage report. (Engineering) 2. The stage-storage table indicates that the maximum stage for the 100-year - 3-day storm event is 7.0 feet, NAVD; however, the statement in the drainage report indicates 6.78. Please revise the report for consistency. (Engineering) 3. The rainfall indicated in the drainage report for the 25-year 3-day storm event is 14 inches; however, the narrative in the report indicates 13.59. Please revise the report for consistency. (Engineering) 4. Due to the 3-foot utility easement (UE) at the rear of the property, ‘No Objection’ letters from the Utility(ies) are required to confirm that the wall may be installed inside the UE. EOR is to coordinate with the owner and surveyor to address this on the plat that is underway. (Engineering) 5. In the event that the proposed construction causes adverse drainage effects to the surrounding areas, it is the responsibility of the owner of the development to address the concerns of the neighbors and provide a solution at the owner’s expense. (Engineering) 6. Provide the Broward County Water and Wastewater availability letter and the waste management letter confirming that they have the capacity for the project. (Engineering) 7. Any road cuts for utilities, curb cuts and/or others with the City ROW shall be restored to full lane width for 50' minimum length centered on the proposed cut. (Engineering) 8. Demolition Plan and Erosion Control Plan and details are required at building permitting. (Engineering) 9. Additional comments may apply and will need to be addressed prior to Building Permit approval. (Engineering) 10. Provide BC standard details for pavement marking and signage. All traffic control signs shall conform to Broward County Traffic Engineering (BCTED) and MUTCD standards. BCTED signs specifications consist of Type XI retroreflective sheeting materials except for school zone and pedestrian signs which shall be comprised of retroreflective fluorescent yellow-green sheeting certified type IV. (Engineering) 3 RESOLUTION #2025-044 11. All pavement markings shall be alkyd-based thermoplastic and fully retro-reflectorized, per BCTED specifications with the exception of parking stall striping. (Engineering) 12. Provide Maintenance of Traffic (MOT) Plan by a licensed General Contractor/Professional Engineer in the State of Florida (if applicable). (Engineering) 13. Detailed and complete engineering plans will be required prior to Building and R/W permit approval. (Engineering) 14. Provide utility piping conflict details plan, along with documentation to demonstrate acceptability of the separation between water, sanitary, storm-water service lines, etc. (Engineering) 15. Show also all existing and proposed utilities on the landscaping plans for potential conflicts. (Engineering) 16. Provide regulatory agencies' approval documentation and Permits/Licenses (as applicable) as part of the final submittal, prior to issuance of the Building Permit (South Florida Water Management District (SFWMD), Broward County Surface Water License, Broward County EPGMD Wastewater Permit / BC Water and Wastewater Approval, Florida Department of Environmental Protection, FDOT, BC Environmental, BC Aviation, BCTED etc.). Also, include Utility / Right of Way Permits from the City, Broward County, and State Roads as applicable. (Engineering) 17. Provide pertinent bylaws and deed restrictions, including disclosure of the dry retention areas and the required maintenance of those areas for future homeowners in a contract disclosure for a sale purchase, or in lease agreements for City Attorney review before permit issuance. (Planning & Zoning). 18. Provide estimated construction value for development so that impact fees may be determined. (Planning & Zoning) 19. Recreation And Open Space Impact Fee: In accordance with Resolution 2015-071, $1,825.00, per Dwelling, must be paid for Recreation and Open Space Impacts at the time the building permit is issued. A total of $7,300.00 ($1,825 x 4 units) will be due at the time of the building permit. (Planning & Zoning) 20. The developer is required to participate in the City’s Public Art program by payment into the City’s Public Art fund or through payment and installation of public art. The amount of the Public Art Fund contribution is dependent on the value of the construction which will be established at the time of building permit submittal. (Planning & Zoning) 21. For all projects resulting in the buildout of the site, construction staging cannot occur on- site and must obtain Staging Plan approval by the Community Development Director prior to the issuance of a building permit. The Staging Plan must include but is not limited to the location of equipment and materials during construction. (Planning & Zoning) 22. For all projects resulting in the buildout of the site, such that construction staging cannot occur on-site, the applicant must obtain Maintenance of Traffic Plan approval by the City Engineer for the period of construction prior to issuance of a building permit. (Planning & Zoning) 23. Per O-2017-027 & O-2018-019. Commercial properties under construction are required to provide security to fencing with screening showing project rendering covering at least 75% 4 RESOLUTION #2025-044 of the length of the fence along an arterial or state right-of-way & 25% for local roads and must include the name and intended use of the project, project rendering, project website address, and owner or agent, the telephone number for the owner or agent, and the name and an emergency contact telephone number of the general contractor. Provide screen details with the next submittal. The City Commission must approve the use of the City Logo. (Planning & Zoning) 24. Provide access easement recordation for lots 1 through 4 prior to the building permit. (Planning & Zoning) 25. Provide a traffic statement by an engineer in lieu of a traffic study prior to the building permit. (Planning & Zoning) 26. Provide drainage calculations and pervious area calculations for each single-family lot to ensure each parcel meets code requirements. Revise plans accordingly prior to the building permit. (Planning & Zoning) 27. The tree symbols for existing trees #38, #40, #41 should be changed from “Remain” to “Remove” (Landscape) 28. Proposed landscape trees will conflict with the proposed drainage lines and inlets along the entrance driveway, the proposed light directly north of building #1, and the proposed sewer line leaving Unit #1. Realign utilities and/or trees to reduce conflicts. (Landscape) 29. Tree #10 is proposed for removal but has no responsible canopy area in the table. Add tree #10 canopy area to the mitigation requirements calculations table. In addition, the pricing calculation below the Proposed Canopy Mitigation Table is missing the 2.7 installation and establishment multiplier. Update the calculations accordingly. Add the required and provided totals for each separate code section so staff can verify the quantity of surplus/mitigation trees. (Landscape) 30. Mitigation requirements and mitigation provided have been added but will need to be updated based on the landscape conditions above. (Landscape) 31. The updated plan LSM-1 lists the applicable code sections requested in the prior comment but does not provide the total required and total provided for each. Update the provided code requirements list to create a table which 1) lists vertically each requirement, 2) provides the total area or linear footage applicable to each code criterion, 3) lists the required number of trees or shrubs to satisfy each category, then lists the total amount of trees or shrubs actually provided in the proposed landscape plan, e.g., 275-90(B)(2) – VUA buffer: XXX linear feet: XX required: XY provided). For clarity, the east, west, and south buffers will be landscaped in accordance with Sec. 275-130, and the north boundary and access drive will be landscaped in accordance with Sec. 275-90(B)(2). (Landscape) 32. The plant lists indicate 11 new VUA trees are proposed but the number of new tree symbols on the plan is 12. Update Note 2 in the bottom-right corner of LSM -1 to indicate lots 2, 3, and 4 only. The required/installed landscaping must continue to be shown and tabulated for Unit #1 since it has already been built. (Landscape) 33. An additional VUA buffer tree is required at the east end of the driveway in front of UNIT #4. (Landscape) 34. Provide existing and proposed topographic elevations on the plan view so staff can evaluate where grade changes may adversely affect existing landscaping “to remain”. (Landscape) 5 RESOLUTION #2025-044 Section 4. That pursuant to Section 635-100 “Expiration of Site Plans” of the Land Development Code, Site Plan (SP-73-18) approval shall automatically expire and become null and void unless the Applicant files a complete building permit application with construction drawings for the improvements shown on the Site Plan within eighteen (18) months from the date of this Resolution. Section 5. That such application must be reviewed by the Broward County Aviation Department; the point of contact is William Castillo, Evaluation and Plan Administrator, located at 2200 SW 45 Street. Suite 101, Dania Beach. Florida 13312 (954) 359-2291. Section 6. That the issuance of a development permit by a municipality does not in any way create any right on the part of an Applicant to obtain a permit from a state or federal agency and does not create any liability on the part of the municipality for issuance of the permit if the Applicant fails to obtain requisite approvals or does not fulfill the obligations imposed by a state or federal agency, or undertakes actions that result in a violation of state or federal law. Section 7. That the associated Planning & Zoning Division Staff Report prepared for the above application(s) is incorporated into this resolution as findings of fact. Section 8. That all resolutions or parts of resolutions in conflict with this Resolution are repealed to the extent of such conflict. Section 9. That this Resolution shall be effective l0 days after passage. PASSED AND ADOPTED on March 31, 2025. Motion by Vice Mayor Salvino second by Commissioner Rimoli. FINAL VOTE ON ADOPTION: Unanimous X Yes No Commissioner Lori Lewellen ____ ____ Commissioner Luis Rimoli ____ ____ Commissioner Archibald J. Ryan IV ____ ____ Vice Mayor Marco Salvino ____ ____ Mayor Joyce L. Davis ____ ____ 6 RESOLUTION #2025-044 ATTEST: ELORA RIERA, MMC JOYCE L. DAVIS CITY CLERK MAYOR APPROVED AS TO FORM AND CORRECTNESS: EVE A. BOUTSIS CITY ATTORNEY 7 RESOLUTION #2025-044 EXHIBIT “A” LEGAL DESCRIPTION 8 RESOLUTION #2025-044 EXHIBIT “B” SITE PLAN (SP-073-18) C SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION PR O J E C T N A M E A D D R E S S : ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. 13 4 2 0 S W 3 6 t h S T R E E T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . CO V E R S H E E T SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A LOCATION MAP 4432 SW 52ND STREET DANIA BEACH, FLORIDA SINGLE FAMILY RESIDENCES SHEET INDEX:SHEET NO: NOVEMBER 2019 011219 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 1. COVER SHEET 2. SURVEY 3. PROPOSED SITE PLAN 4. FLOOR PLANS 7. TYPICAL FLOOR PLAN 8. PAVING GRADING & DRAINAGE PLAN 9. WATER & SEWER PLAN 10. PAVEMENT MARKING & SIGNAGE PLAN 11. PHOTOMETRIC SITE PLAN 13. EROSION CONTROL PLAN 15. LANDSCAPING PLAN 16. LANDSCAPING DETAIL 17. IRRIGATION PLAN C S A-1 A-2 A-5 C-1 C-2 C-3 PH-1 C-5 L-1 L-2 L-3 6. ELEVATIONS PLAN A-4 5. ELEVATIONS PLAN A-3 18. EXISTING TREE SURVEY TD-1 12. FIRE RESCUE PLAN C-4 14. NOTES AND SPECIFICATIONS C-6 & SIGHT DISTANCE 19. LANDSCAPING MITIGATION PLAN LSM-1 GMAX LEGAL DESCRIPTION THE SOUTH 100.00 FEET OF LOTS 7, 8, 9 AND 10, AND THE EAST 6.00 FEET OF THE NORTH 116.00 FEET OF LOT 8, AND THE WEST 44.00 FEET OF THE NORTH 116.00 FEET OF LOT 9, ALL IN BLOCK 5, "BROWARD GARDENS", ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 21, PAGE 48, OF THE PUBLIC RECORDS OF BROWARD COUNTY, FLORIDA. SAID LANDS LYING AND BEING IN THE CITY OF DANIA BEACH, BROWARD COUNTY, FLORIDA, AND CONTAIN 0.794 ACRES, MORE OR LESS. L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 2 7 16 : 4 7 : 1 3 - 0 6 ' 0 0 ' C-1 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. SECTION A-A N.T.S. N.T.S. SECTION D-D A B C N.T.S.C A B A B C SECTION B-B N.T.S. A A B B D D PA V I N G G R A D I N G A N D DR A I N A G E P L A N PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A NOVEMBER 2019 011219 SCALE:0'-1" = 20'-0" 0' 20' 40' 80' DRAINAGE PLAN PAVING GRADING AND S.W. 52nd STREET CL EDGE OF PAVEMENT EDGE OF PAVEMENT N.R.O.W. LINE NORTH PROPERTY LINE S.R.O.W. LINE SOUTH PROPERTY LINE 22 6 ' T O E X . F . H . AA 4:1 F.F.E. 7.25' NAVD 88 F.F.E. 7.25' NAVD 88 EE SECTION E-E N.T.S. SECTION F-F N.T.S. PROPOSED 12"X12" COLUMN @ 21' O.C. (ALONG PROPERTY) PROPOSED 4" @ 20' WALL (ALONG PROPERTY) G G CONCRETE PROPOSED 12"X12" COLUMN PROPOSED 4" @ 20' WALL N.T.S. GROUND ELEV. PROPOSED 12"X12" COLUMN PROPOSED 5' WALL (SOLID) L 20' PANEL F F FF 4:1 4:1 F.F.E. 7.25' NAVD 88 F.F.E. 7.25' NAVD 88 4:1 F.F.E. 7.25' NAVD 88 F.F.E. 7.25' NAVD 88 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ WALLS SHALL BE DESIGN TO MEET NOTE : AND OBTAIN THE PERMIT FROM BUILDING DEPT., AND SHALL BE ABLE TO CONTAIN THE 25-YEAR 3-DAY LOAD CAPACITY & BE AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. G G WATERPROOF UP TO 25-YEARS 3-DAY EVENT ELEVATION. (6.47' NAVD "88") (TYP. ALL) 3-DAY EVENT ELEVATION. (6.47' NAVD) WATERPROOF TO 25-YR WALLS SHALL FBC 2023 8th Edition TOP OF WALL ELEVATION 10.00' NAVD "88" UNIT #1 UNIT #2 UNIT #3 UNIT #4 TOP OF WALL ELEVATION (10.00' NAVD "88") PROPOSED 5' WALL PROPOSED 12"X12" COLUMN (TYP. ALL) 3-DAY EVENT ELEVATION.(6.47' NAVD) WATERPROOF TO 25-YR WALLS SHALL TOP OF WALL ELEVATION (10.00' NAVD "88") PROPOSED 5' WALL PROPOSED 12"X12" COLUMN TOP OF WALL (6.47' NAVD "88") TOP OF WALL (6.47' NAVD "88") 4" WALL TOP OF WALL (6.47' NAVD "88") 4" WALL TOP OF WALL (6.47' NAVD "88") CL CL SWALE CENTER LINE SWALE CENTER LINE UTILITY EASEMENT END OF WALLEND OF WALL PROPOSED 5' WALL PROPOSED 5' WALL PROPOSED 5' WALL PROPOSED 5' WALL (TYP. ALL) 3-DAY EVENT ELEVATION. (6.47' NAVD) WATERPROOF TO 25-YR WALLS SHALL TOP OF WALL ELEVATION (10.00' NAVD "88") PROPOSED 5' WALL PROPOSED 12"X12" COLUMN L I C ENSE ** FLOR I D A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 12 : 5 7 : 5 0 - 0 6 ' 0 0 ' C-2 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. WA T E R S E W E R P L A N S.W. 52nd STREET 484' TO EX. F.H.378' TO EX. F.H. 22 6 ' T O E X . F . H . S1 Crossing Details PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A NOVEMBER 2019 011219 SCALE:0'-1" = 20'-0" 0' 20' 40' 80' WATER & SEWER PLAN CL EDGE OF PAVEMENT EDGE OF PAVEMENT S.R.O.W. LINE SOUTH PROPERTY LINE N.R.O.W. LINE NORTH PROPERTY LINE 145' TO HOUSE130' TO HOUSE CLEAN OUT FLOW DIRECTION LEGEND : C / O SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 THE WATER / SEWER USAGE IS 145 GALLONS PER UNIT WATER & SEWER: PER DAY TOTAL FOR FOUR UNITS WILL BE 580 GALLONS / DAY. SOLID WASTE PER HOUSE HOLD IS 8.9 lb PER RESIDENT PER DAY, SOLID WASTE: FOR THE SITE WILL BE 35.6 lb / DAY. UNIT #1 UNIT #2 UNIT #3 UNIT #4 PROPOSED DOUBLE 58" WATER METER PROPOSED DOUBLE 58" WATER METER L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 12 : 5 8 : 1 8 - 0 6 ' 0 0 ' C-3 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. PA V E M E N T M A R K I N G A N D PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A NOVEMBER 2019 011219 S.W. 52nd STREET SCALE:0'-1" = 20'-0" 0' 20' 40' 80' CL EDGE OF PAVEMENT EDGE OF PAVEMENT S.R.O.W. LINE SOUTH PROPERTY LINE N.R.O.W. LINE NORTH PROPERTY LINE ROAD SHALL BE DESIGN TO HOLD ADD NOTE 32 TONS FIRE TRUCK SIGNAGE PLAN & SIGHT DISTANCE PAVEMENT MARKING AND 4" DOUBLE SOLID YELLOW 24" WHITE STOP BAR, PAVAMENT, MARKINGAND AND SIGNAGE NOTES x ALL PAVEMENT, MARKING AND SIGNAGE SHALL BE IN ACCORDANCE WITH THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. x ALL PAVEMENT, MARKING SHALL BE THERMOPLASTIC AS PER BROWARD COUNTY TRAFFIC ENGINEERING STANDARD. x R1-1 STOP SIGN SHALL BE HIGH INTENSITY REFLECTORIZED MATERIAL. x STOP SIGN SHALL BE 30" X 30" HIGH INTENSITY REFLECTIVE MATERIAL. x PAVEMENT MARKING SHALL BE REFLECTIVE THERMO PLASTIC, SHALL CONFORM W/ FDOT STANDARD SPECIFICATION AND BROWARD COUNTY STANDARD AND SPECIFICATION. STOP SW 52 Streetnd SI G N A G E P L A N & EDGE OF PAVEMENT EDGE OF PAVEMENT - POSTED SPEED LIMIT SIGN IS 30 MPH - SIGHT DISTANCE IS 200 FT BASE ON GREEN BOOK 2'-4' SKIP 4"WHITE 2'-4' SKIP 4"WHITE NO PARKING SIGN NO PARKING SIGN NO PARKING SIGN NO PARKING SIGN 4" DOUBLE SOLID YELLOW NO PARKING SIGN NO PARKING SIGN SI G H T D I S T A N C E SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. UNIT #1 UNIT #2 UNIT #3 UNIT #4 L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 12 : 5 8 : 4 4 - 0 6 ' 0 0 ' C-4 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. FI R E R E S C U E / PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A NOVEMBER 2019 011219 S.W. 52nd STREET 484' TO EXISTING F.H.378' TO EXISTING F.H. SCALE:0'-1" = 20'-0" 0' 20' 40' 80' CIRCULATION PLAN CL EDGE OF PAVEMENT EDGE OF PAVEMENT S.R.O.W. LINE SOUTH PROPERTY LINE N.R.O.W. LINE NORTH PROPERTY LINE 22 6 ' T O E X I S T I N G F . H . 145' TO HOUSE130' TO HOUSE FIRE SAFTY NOTES 1.AS PER TABLE 18.4.5.1.2. THE MIN. REQUIRED FLOW FOR RESIDENTIAL BUILDING IS 1500 GPM FOR 2 HOURS FLOW DURATION, EXISTING FIRE HYDRANT & PROPOSED FIRE HYDRANT WILL PROVIDE MUCH MORE THAN 1500 GPM. (PLEASE SEE ATTACH REPORT FOR FLOW TEST). 2. ALL THE PORTION OF AN EXTERIOR WALL OF THE FIRST STORY OF THE BUILDING IS LOCATED NOT MORE THAN 150 ft FROM DEPARTMENT ACCESS AS MEASURED BY AN APPROVED ROUTE THE AROUND THE EXTERIOR OF BUILDING OR FACILITY, IN THE EVENT 150 ft REQUIREMENT NOT MEET FIRE SPRINKLER SHALL BE INSTALL IN THE BUILDING. 3. PROPOSED FIRE HYDRANT LOCATED IN S.W. 52nd STREET WHICH IS ALMOST 200 ft. FROM HOUSE. 4. NO SPRINKLER SYSTEM BEEN PROPOSED FOR BUILDING. 5. NO REDUCTION FOR FLOW CALCULATION. ROAD SHALL BE DESIGN TO HOLD ADD NOTE 32 TONS FIRE TRUCK SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 PROPOSED FIRE HYDRANT FIRE RESCUE/ GARBAGE TRUCK GA R B A G E T R U C K CI R C U L A T I O N P L A N UNIT #1 UNIT #2 UNIT #3 UNIT #4 L IC ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 12 : 5 9 : 1 2 - 0 6 ' 0 0 ' ER O S I O N C O N T R O L P L A N SECTION A-A TEMPORARY GRAVEL CONSTRUCTION ENTRANCE N.T.S. C-5 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION PR O J E C T N A M E A D D R E S S : ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A NOVEMBER 2019 011219 SCALE:0'-1" = 20'-0" 0' 20' 40' 80' EROSION CONTROL PLAN S.W. 52nd STREET CL EDGE OF PAVEMENT EDGE OF PAVEMENT S.R.O.W. LINE SOUTH PROPERTY LINE N.R.O.W. LINE NORTH PROPERTY LINE SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 1 08/02/23 ENGINEERING This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. CL I UNIT #1 UNIT #2 UNIT #3 UNIT #4 L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 12 : 5 9 : 3 9 - 0 6 ' 0 0 ' NO T E S A N D S P E C I F I C A T I O N S C-6 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION PR O J E C T N A M E A D D R E S S : ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A NOVEMBER 2019 011219 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 13 : 0 0 : 1 2 - 0 6 ' 0 0 ' A-1 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. PR O P O S E D S I T E P L A N S.W. 52nd STREET PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A PROPOSED SITE PLAN SCALE:0'-1" = 20'-0" 0' 20' 40' 80' CL 138.00' (N.90 00' 00"E.)100.00' (N.90 00' 00"E.) 288.00' (S.90 00' 00"W.) 10 0 . 0 0 ' ( S . 0 0 0 2 ' 5 5 " W . ) 10 0 . 0 0 ' ( N . 0 0 0 2 ' 5 5 " E . ) 11 6 . 0 0 ' ( N 0 0 0 2 ' 5 5 " E . ) 11 6 . 0 0 ' ( S 0 0 0 2 ' 5 5 " W . ) (N.90 00' 00"E.) 50.00' EDGE OF PAVEMENT EDGE OF PAVEMENT S.R.O.W. LINE SOUTH PROPERTY LINE N.R.O.W. LINE NORTH PROPERTY LINE 346 00 SF. 6148 SF. 100% 17.77% GROSS AREA TOTAL BUILDING 716 SF. 2.07%DRIVEWAY 8124 SF. 23.48%ROAD SITE DATA : 19,820 SF. 57.28%GREEN FUTURE LAND USE IS RESIDENTIAL. ZONING IS RD-8000 RESIDENTIAL (SINGLE FAMILY DETACHED) 346 00 SF. 100%NET AREA 14,780 SF. 42.72%TOTAL IMPERVIOUS ALLOWABLE HEIGHT IS 25' HOUSES WILL BE ONE STORY DENSITY : TOTAL SITE AREA : 0.794 AC PERMITTED UNITS 6.35 UNITS ZONE RD-8000 & WILL BE LESS THAN 25' (USING R-S 6000 FOR SINGLE FAMILY DETACHED) REQUIRED 14'-7" PROVIDED 8'-8" TO 23'-8" SET BACK: EAST 15'-0" 15'-0"SOUTH 14'-7" 8'-8" TO 23'-8"WEST 25'-0" 45'-0"NORTH EACH HOUSE WILL BE AROUND 1420 SQ.FT. WITH PARKING : 3 BEDROOM WHICH REQUIRED 2 PARKING, WHICH HAS BEEN PROVIDED FRONT OF EACH HOUSE. WHICH OWNED & MAINTAINED BY OWNER / DEVELOPER CHARACTERISTIC : OF PROPERTY. THE LANDSCAPING,IRRIGATION, ROAD, LIGHTINGS, SEWER WATER AND DRAINAGE WILL BE PRIVATE AND GMAX HOUSES ARE RENTAL RESIDENTIAL HOMES WILL BE OWNED AND MAINTAIN BY OWNER OF PROPERTY. F.P&L WILL BE PROVIDER FOR ELECTRICAL AND BROWARD COUNTY WILL BE RESPONSIBLE FOR WATER & SEWER. MAIL BOX LOCATION : NO PHASING PLANED FOR CONSTRUCTION. ALL THE PROPOSED MAIL BOX LOCATION WILL BE REVIEWED & APPROVED BY THE POST OFFICE PRIOR TO INSTALLATION (PROPOSED MAIL BOXES WILL BE FRONT OF EACH UNIT). PROPOSING TO INSTALL IMPACT DOORS & WINDOWS & INSTALL NOISE MITIGATION : INSULATION TO REDUCE & CONTROL THE NOISE. BROWARD COUNTY WILL BE THE PROVIDER UTILITIES : FOR WATER & THE SEWER. ROAD DESIGN : ROAD SHALL BE DESIGN TO HOLD 32 TONS FIRE TRUCK. PROPOSED 12"X12" COLUMN PROPOSED 5' WALL (SOLID) L 20' PANEL SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. THE WATER / SEWER USAGE IS 145 GALLONS PER UNIT WATER & SEWER: PER DAY TOTAL FOR FOUR UNITS WILL BE 580 GALLONS / DAY. SOLID WASTE PER HOUSE HOLD IS 8.9 lb PER RESIDENT PER DAY, SOLID WASTE: FOR THE SITE WILL BE 35.6 lb / DAY. 0.794 0.14 0.016 0.186 0.455 0.794 0.339 .AC PROPOSED 4 SINGLE FAMILY DETACHED ONE STORY SINGLE FAMILY HOME ONE STORY SINGLE FAMILY HOME TWO STORY RENTAL APT. ON E S T O R Y SI N G L E F A M I L Y H O M E ON E S T O R Y SI N G L E F A M I L Y H O M E AC C E S S EA S E M E N T ACCESS EASEMENT UNIT #1 UNIT #2 UNIT #3 UNIT #4 ( 1420 SQ.FT. UNIT #1) CL CL SWALE CENTER LINE SWALE CENTER LINE ACCESS EASEMENT TRAFFIC DIRECTION TRAFFIC DIRECTION LEGEND : LIMIT OF PROPOSED 5' WALL PROPOSED 5' WALL PROPOSED 5' WALL PROPOSED 5' WALL NOVEMBER 2019 011219 ( 1537 SQ.FT. UNIT #2- #3, #4) GMAX LEGAL DESCRIPTION THE SOUTH 100.00 FEET OF LOTS 7, 8, 9 AND 10, AND THE EAST 6.00 FEET OF THE NORTH 116.00 FEET OF LOT 8, AND THE WEST 44.00 FEET OF THE NORTH 116.00 FEET OF LOT 9, ALL IN BLOCK 5, "BROWARD GARDENS", ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 21, PAGE 48, OF THE PUBLIC RECORDS OF BROWARD COUNTY, FLORIDA. SAID LANDS LYING AND BEING IN THE CITY OF DANIA BEACH, BROWARD COUNTY, FLORIDA, AND CONTAIN 0.794 ACRES, MORE OR LESS. L I C E NSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 2 7 17 : 3 6 : 3 8 - 0 6 ' 0 0 ' FLOOR PLAN LEFT SIDE ELEVATION RIGHT SIDE ELEVATION FRONT ELEVATION REAR ELEVATION N A-2 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. FL O O R P L A N PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A FEBRUARY 20 010220 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. AN D E L E V A T I O N S LO T - 8 B L O C K - 5 7.25 NAVD 88 LOTS #1,2,3 & 4 FINISH FLOOR ELEV. 7,200 SQ.FT.TOTAL LOT SIZE 6,148 SQ.FT.TOTAL LOT BUILDING (4) 19,820 SQ.FT.TOTAL LOT PERVIOUS 14,780 SQ.FT.TOTAL IMPERVIOUS ROOF LINE L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 12 : 5 6 : 5 2 - 0 6 ' 0 0 ' 3' UTILITY EASEMENT UNIT #1 UNIT #2 UNIT #3 UNIT #4 S.W. 52nd STREET NOTE: 1· SCREEN AROUND (3 SITE MIN.) PROPOSED A/C EQUIPMENT AND IRRIGATION PUMP WITH 30" HIGH SHRUB SPACING 24" O.C. 2· LANDSCAPING FOR EACH LOT WILL BE PROVIDED AT TIME OF HOUSE PERMIT FOR INDIVIDUAL LOTS NO PARKING SIGN NO PARKING SIGN PROPOSED WATER METER PROPOSED WATER METER FIRE HYDRANT CL CL LIGHT POLE #1 LIGHT POLE #2 LIGHT POLE #4 LIGHT POLE #3 LIGHT POLE #5 LIGHT POLE #6 NOTE: 1- ALL THE EQUIPMENT SHALL BE SCREENED ON THREE (3) SIDE W/ LANDSCAPE MATERIAL 30" HEIGHT, 24" O.C. 2- ALL THE PROPOSED TREE SHALL BE INSTALL 15' FROM STRUCTURE AND 20' FROM OTHER SHADE TREE. 3- SHADE TREE IN STREET SHALL BE MIN. 6' FROM EDGE OF PAVEMENT. 4- PLACE BAHIA SOD (PASPALUM NOTATUM) SOLID EVEN AT THE SITE AND UN PAVED ROAD R-O-W. 5- AREA BETWEEN 2.5' AND 8' ABOVE ELEV. OF ADJOINING PAVEMENT MUST BE CLEAR OF ANY OBSTRUCTION WITHIN SIGHT TRIANGLE. 6- NO IRRIGATION ALL LANDSCAPE PLAN SHALL BE HAND WATERED UNTIL ESTABLISHED. 7- ALL SHADE CANOPY TREES SHALL BE CATEGORY 1 TREE. 8- NON SHADE TREES SHALL BE LOCATED MIN. 8' AWAY FROM STRUCTURES & 15' FROM OTHER TREES. 12'-14' HG X 5' SPR, 3" DBH. 12'-14' HG X 5' SPR, 3" DBH. QUANTITY MAHOGANY COMMON NAME BOTANICAL NAME SWIETENIA MAHOGANI SPECIFICATIONSMARK 2 Quercus VIRGINIANALIVE OAK 1 24" X 30" HG, 3 GA. 24" O.C.CHRYSOBALANUS ICACO COCOPLUM20 A B C NATIVE YES YES YES 12'-14' HG X 5' SPR, 3" DBH. QUANTITY COMMON NAME BOTANICAL NAME SPECIFICATIONSMARK 11 Quercus VIRGINIANALIVE OAK 24" X 30" HG, 3 GA. 24" O.C.CHRYSOBALANUS ICACO COCOPLUM194 B C NATIVE YES YES - PLACE BAHIA SOD (PASPALUM NOTATUM) SOLID EVEN - PLACE 2" MULCH AROUND THE TREES & BOTTOM OF SHRUBS USE ORGANIC MATERIAL ONLY. - PLACE BAHIA SOD (PASPALUM NOTATUM) SOLID EVEN - PLACE 2" MULCH AROUND THE TREES & BOTTOM OF SHRUBS USE ORGANIC MATERIAL ONLY. PROPOSED LOTS LANDSCAPING SCHEDULE FOR EACH LOT (EXISTING NOT INCLUDED) PROPOSED ADDITIONAL TREES WITHIN THE SITE (VEHICULAR USE AREA) 12'-14' HG X 5' SPR, 3" DBH. 12'-14' HG X 5' SPR, 3" DBH. QUANTITY MAHOGANY COMMON NAME BOTANICAL NAME SWIETENIA MAHOGANI SPECIFICATIONSMARK 8 Quercus VIRGINIANALIVE OAK 4 24" X 30" HG, 3 GA. 24" O.C.CHRYSOBALANUS ICACO COCOPLUM80 A B C NATIVE YES YES YES TOTAL ON SITE FOR ALL FOUR UNIT LS-1 / 2 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. SI T E L A N D S C A P E P L A N PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A FEBRUARY 20 010220 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 13 : 0 0 : 5 1 - 0 6 ' 0 0 ' LS-2 / 2 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. LO T L A N D S C A P E P L A N PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A FEBRUARY 20 010220 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. UNIT #1 LIGHT POLE #1 L IC ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 13 : 0 1 : 1 9 - 0 6 ' 0 0 ' NOTE: 1· SCREEN AROUND (3 SITE MIN.) PROPOSED A/C EQUIPMENT AND IRRIGATION PUMP WITH 30" HIGH SHRUB SPACING 24" O.C. 2· LANDSCAPING FOR EACH LOT WILL BE PROVIDED AT TIME OF HOUSE PERMIT FOR INDIVIDUAL LOTS LIGHT POLE #1 LIGHT POLE #4 NOTE: 1- ALL THE EQUIPMENT SHALL BE SCREENED ON THREE (3) SIDE W/ LANDSCAPE MATERIAL 30" HEIGHT, 24" O.C. 2- ALL THE PROPOSED TREE SHALL BE INSTALL 15' FROM STRUCTURE AND 20' FROM OTHER SHADE TREE. 3- SHADE TREE IN STREET SHALL BE MIN. 6' FROM EDGE OF PAVEMENT. 4- PLACE BAHIA SOD (PASPALUM NOTATUM) SOLID EVEN AT THE SITE AND UN PAVED ROAD R-O-W. 5- AREA BETWEEN 2.5' AND 8' ABOVE ELEV. OF ADJOINING PAVEMENT MUST BE CLEAR OF ANY OBSTRUCTION WITHIN SIGHT TRIANGLE. 6- NO IRRIGATION ALL LANDSCAPE PLAN SHALL BE HAND WATERED UNTIL ESTABLISHED. 7- ALL SHADE CANOPY TREES SHALL BE CATEGORY 1 TREE. 8- NON SHADE TREES SHALL BE LOCATED MIN. 8' AWAY FROM STRUCTURES & 15' FROM OTHER TREES. 12'-14' HG X 5' SPR, 3" DBH. 12'-14' HG X 5' SPR, 3" DBH. QUANTITY MAHOGANY COMMON NAME BOTANICAL NAME SWIETENIA MAHOGANI SPECIFICATIONSMARK 2 Quercus VIRGINIANALIVE OAK 1 24" X 30" HG, 3 GA. 24" O.C.CHRYSOBALANUS ICACO COCOPLUM20 A B C NATIVE YES YES YES 12'-14' HG X 5' SPR, 3" DBH. QUANTITY COMMON NAME BOTANICAL NAME SPECIFICATIONSMARK 11 Quercus VIRGINIANALIVE OAK 24" X 30" HG, 3 GA. 24" O.C.CHRYSOBALANUS ICACO COCOPLUM194 B C NATIVE YES YES - PLACE BAHIA SOD (PASPALUM NOTATUM) SOLID EVEN - PLACE 2" MULCH AROUND THE TREES & BOTTOM OF SHRUBS USE ORGANIC MATERIAL ONLY. - PLACE BAHIA SOD (PASPALUM NOTATUM) SOLID EVEN - PLACE 2" MULCH AROUND THE TREES & BOTTOM OF SHRUBS USE ORGANIC MATERIAL ONLY. PROPOSED LOTS LANDSCAPING SCHEDULE FOR EACH LOT (EXISTING NOT INCLUDED) PROPOSED ADDITIONAL TREES WITHIN THE SITE (VEHICULAR USE AREA) 12'-14' HG X 5' SPR, 3" DBH. 12'-14' HG X 5' SPR, 3" DBH. QUANTITY MAHOGANY COMMON NAME BOTANICAL NAME SWIETENIA MAHOGANI SPECIFICATIONSMARK 8 Quercus VIRGINIANALIVE OAK 4 24" X 30" HG, 3 GA. 24" O.C.CHRYSOBALANUS ICACO COCOPLUM80 A B C NATIVE YES YES YES TOTAL ON SITE FOR ALL FOUR UNIT LSM-1 SHEET CONSTRUCTION DATE BID DATE DATE FILE NAME SCALE CHECKED BY DRAWN BY JOB NUM NO.DATE DESCRIPTION REVISION ALL DRAWINGS AND WRITTEN MATERIALS APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK IF A.E.C. INC. AND MAY NOT BE DUPLICATED, USED, OR DISCLOSED WITHOUT THE EXPRESS WRITTEN CONSENT OF A.A.C. INC. ( C) 2003 THE ENGINEER HAS PREPARED PLANS, CALCULATIONS AND SPECIFICATIONS TO THE BEST OF HIS ABILITIES IN COMPLIANCE WHIT THE FLORIDA BUILDING CODE 104.1.5.2004 G.K. S.B. SI T E L A N D S C A P E PR O J E C T N A M E A D D R E S S : SI N G L E F A M I L Y R E S I D E N C E S 44 3 2 S W 5 2 N D S T R E E T DA N I A B E A C H , F L O R I D A FEBRUARY 20 010220 SEAL GH A S E M K H A V A N I N P . E . F R # 4 1 9 5 5 DA T E : _ _ _ / _ _ _ / _ _ _ AB A E N G I N E E R I N G A N D CO N S T R U C T I O N I N C . 13 4 2 0 S W 3 6 t h C O U R T DA V I E F L 3 3 3 3 0 PH O N E ( 9 5 4 ) 2 2 4 - 1 3 8 0 This item has been digitally signed and sealed by GHASEM KHAVANIN on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. MITIGATION PLAN SITE LANDSCAPE MI T I G A T I O N P L A N MITIGATION PROPOSED CANOPY MITIGATION TABLE REQUIREMENTCATEGORY SQUARE CANOPYLOSS MULTIPLIER CATEGORY IINVASIVECANOPY CATEGORY IIINVASIVECANOPY NON-INVASIVE CANOPY SPECIMEN TREE VALVE TOTAL 4,799 0 410 N/A 5,209 25% (0.25) 100% 150% (1.5) N/A N/A SQUARE FOOT CANOPYMITIGATIONREGUIRED 1,199.75 0 615 N/A 1,814.75 APPROVEDVALVE N/A N/A N/A NO LIVE OAK BEEN PROPOSED TO BE REMOVED CATEGORY IB REPLACEMENT TREE PRICE 1814.75 300 = 6.050 SAY 7X225= 1,575 SECTION OF CODE APPLICABLE TO THE PROJECT SEC 275-170 (B) SCREENING SHRUBS SEC 825-100 (A)(5) 1.5(150%) CANOPY MITIGATION MULTIPLIER FOR NON-INVASIVE SEC 825-100 (A)(6) 0.25(25%) CANOPY MITIGATION MULTIPLIER FOR CAT I INVASIVE SEC 825-100 (A)(7) CANOPY MITIGATION REQUIRED SEC 875-90 275-80 (H), 275-90, 275-160, 275-170, 275-60 & 275-190 (D-G) 3' UTILITY EASEMENT UNIT #1 UNIT #2 UNIT #3 UNIT #4 S.W. 52nd STREET NO PARKING SIGN NO PARKING SIGN PROPOSED WATER METER PROPOSED WATER METER FIRE HYDRANT CL CL LIGHT POLE #2 LIGHT POLE #3 LIGHT POLE #5 LIGHT POLE #6 L I C ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 2 . 0 6 13 : 0 2 : 2 0 - 0 6 ' 0 0 ' PHOTOMETRIC PLAN SCALE:0'-1" = 10'-0" 0' 10' 20' 40' TYPICAL LIGHT POLE FOUNDATION L IC ENSE ** FLORID A ST A T E O F NO . 4 1 9 5 5 ** ** Di g i t a l l y s i g n e d by G H A S E M KH A V A N I N Da t e : 20 2 5 . 0 3 . 0 6 16 : 3 9 : 1 1 - 0 6 ' 0 0 '