Loading...
HomeMy WebLinkAboutInv# PCI220859 - PC CONTROLS, INC - 09/27/2021Invoice Date 9/27/2021 Invoice # PCI220859 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Darren Green Maintenance - Lift stations PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 2020-00000030 Terms Net 30 Due Date 10/27/2021 Technician PC/AU Comments CJ Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Multiple Dates of Service Hours - New Technician16 64.00 1,024.00 Hours2 - New Technician 216 32.00 512.00 9/20/21 - Troubleshoot Level Control at Lift Station #8. Found no 4-20 mA Level transmitter attached to the wire. The pump may have sucked transmitter into pump. Note pumps are very loud and check valve arms barely come up. Replace Level transmitter with Keller LevelRat but sensor appears to be bad because it reads 18.6 mA out of the water. Call operations for new sensor but the sensor reads exactly the same. Troubleshoot Backup Level Control. Back up Level control is operational now. Will return tomorrow to continue troubleshooting Primary Level control and assist with pulling pumps to identify why pumps are so loud. Page 1 Invoice Date 9/27/2021 Invoice # PCI220859 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Darren Green Maintenance - Lift stations PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 2020-00000030 Terms Net 30 Due Date 10/27/2021 Technician PC/AU Comments CJ Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date 9/21/20 Return to site and troubleshoot Primary Level control. Found isolator for Telemetry system to have bad input. Disconnect as per Darren because Telemetry does not work and soon to be redone. Assist pulling pump1 - found a lot of rags in volute, also flush check valve before reinstalling pump. Pump now sounds and operates better. Pulled #2 pump found the 4-20 mA sensor previously missing in intake of pump. Remove sensor clean volute of debris and flush check valve. Pump operates and sounds better now. Set Primary Level control insertion depth and back up level control. Test both level controls and alternation of pumps. Lot Material - misc1 15.00 15.00 Page 2 $1,551.00 $1,551.00 $0.00