JOB#DATE PO/REF#DESCRIPTION
17514 12/28/2021 WO-01257235 PENTAIR WARRANTY WO-01257235
SENT BY JOHN KLISE - PENTAIR
ULTRATEMP 120C, STOPPED WORKING THIS IS A COMMERCIAL
PROPERTY AND THEY HAVE 9 HEAT PUMPS IN TOTAL.
CALL ON THE WAY
KNOCK ON DOOR
Job Charges Qty Rate Total
SERVICE CALL. NO WARRANTY ISSUE.
Checked both heaters they would turn off and on checked all
voltage was getting inconsistent readings but heat pumps are all 3
phase they have a safety switch built in the contactor ground wire
on both heat pumps calcified which didn’t allow proper contact
causing the heat pump to lockout the cleaned them and all
working well now
1.00 $120.00 $120.00
Job Subtotal $120.00
Job Total $120.00
CUSTOMER MESSAGE
Thank you for your business!
Invoice Total:$120.00