Loading...
HomeMy WebLinkAboutInv# PCI221161 - PC CONTROLS, INC - 05/16/2022Invoice Date 5/16/2022 Invoice # PCI221161 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Darren Green Maintenance - Lift stations PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 2022-00000042 Terms Net 30 Due Date 6/15/2022 Technician PC/AU Comments Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Hours - Contract 2... Technician4 63.00 252.005/13/2022 Troubleshoot Wastewater flowmeter. On arrival the display was blank. Check 120 VAC and it was there. Remove fuse for flowmeter coil - test and re-install. Display works now. Perform flow verification and certification. Site meter read 100.5% of test meter. Xmtr Fee - Contract Transmitter Certification Fee1 49.00 49.00 Fuel Surcharge - ... Broward and other1 10.00 10.00 $311.00 $311.00 $0.00 P.C. Controls lnc PC CONTROLS 4114 W Palm Aire Dr 141B , Pompano Beach, FL 33069 Phone : (954) 568-9663, Fax: TBD Ir--..J"~ E-mail: pccontrolsinc@ bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit # Test Site Seahaven Marina Lift Station flowmeter District ID # ____ _ Contact Darren Green Number 954 558-2770 Meter Model Rosemount 8750WDMW Serial# 14867114 Meter Accessories: None Pipe Information at test site Material PVC Outside Diameter 3.5" OD Pipe Thickness 0.3" WT Transducer Spacing 1.475" V-Mount Distance from Meter installation is 3 feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ _7.93 ______ GPM Initial Meter Reading at Calibration Start: 438.98 X 1000 End: 439.03 X 1000 ------- 50 Gallons Totalized in 376 Seconds ------Average _7.97 _ GPM Test Meter Reading at Calibration Start: 0 X 1 End : -------49 .7 x 1 49 .7 Gallons Totalized in 376 Seconds ------Average _ 7 .93 _ GPM Meter Tested at _I 00.5 _ % Accuracy Last Meter Test 9/19 --Last Accuracy _99 .2% _ Comments: Prior to calibration meter was reading 100.5% oftest meter -Site meter read 7 .97 GPM and test meter read 7.93 GPM. Performed By: NP Conaway Date: 5/13 /22 Thi s is to certify that the above listed equipment has been_s.a librated and meets or exceeds all published specifications. Calibration was performed using sta~dards ~strum entation whose accuracy is traceable to the N .I.S .T . Signature : N~