Loading...
HomeMy WebLinkAboutInv# PCI221217 - PC CONTROLS, INC - 07/19/2022Invoice Date 7/19/2022 Invoice # PCI221217 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Water Treatment Plant Nate Costa PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 2022-00000042 Terms Net 30 Due Date 8/18/2022 Technician PC Comments Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Hours - Contract 2... Technician8 63.00 504.007/7/2022 Calibrate and certify Distribution Flow, Distribution Pressure, East Supernate Flow, Train1 Concentrate and Train2 Concentrate. Xmtr Fee - Contract Transmitter Certification Fee5 49.00 245.00 Fuel Surcharge - ... Broward and other1 10.00 10.00 $759.00 $759.00 $0.00 PC CONTROLS I r--..J" C::::: CALIBRATION CERTIFICATIONS For City of Dania Beach 6/22 Prepared by P. C. CONTROLS, INC. PC CONTROLS I ::r:-...J C:::: P.C. Controls Inc 4114 W Palm Aire Dr 141B, Pompano Beach, FL 33069 Phone: (954) 568-9663; Fax: TBD E-mail: pccontrolsinc@bellsouth.net Location : City of Dania Beach WTP Function: East Supemate Flowmeter, Fit-123 Technician: NP Conaway Cal. Type: Ultrasonic Comparison Date: 717 122 DueDate: 6/23 Interval: Yearly Test Equipment Used: FUJI Portaflow, Fluke 787 Mfr: Seametrics Full Scale: 100 GPM Input 47.4 47.4 Type: SCADA Measured Output (mA) (v) B A 47.4 11.58 47.4 11.58 01 Full Signal in Req . Output GPM/MGD Scale mNVolt 0 4 0 50 12 50 100 20 100 Transmitter Calibration Data Model#: FT420 Req 'd Output (rnA) (v) Remarks Serial#: 04220600 Line Size: 2" 47.4 AVG.GPM 11.58 mA Receiver Calibration Data Full Scale: l 00 GPM Indication GPM/MGD 0 50 100 Remarks GPM Dial X: l This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications. Calibration was performed using standards and/ ·nstrumentation whose accuracy is traceable to the N.l.S.T. Signature PC CONTROLS :i: :I"'...J ~ P.C . Controls Inc 4114 W Palm Aire Dr 14 IB, Pompano Beach, FL 33069 Phone: (954) 568-9663 , Fax : TBD E-mail: pccontrolsinc@ bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit# 06-00187-W Test Site East Supernatent Flow Transmitter, FIT-123 District ID# ___ _ Contact Nate Costa Number 954 924-3616 Meter Model Seametrics FT440E Serial# 04220600 Meter Accessories: None Pipe Information at test site Material PVC Schedule 40 Outside Diameter 2 .375" OD Pipe Thickness .154" WT Transducer Spacing 0.55" Z-Mount Distance from Meter installation is 10 feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ __ 47.2 _____ GPM Initial Meter Reading at Calibration Start: 8250 __ x _ 1_ End: 8650 ___ x 1 400 Gallons Totalized in 506 Seconds Average_ 4 7.4_ GPM Test Meter Reading at Calibration Start: 0 x 1 End: 400 ___ x 1 --- 400 Gallons Totalized in 508 Seconds Average_ 47 .2 _ GPM Meter Tested at _1004_ % Accuracy Last Meter Test 6/21 Last Accuracy_ I 01. 7% _ Comments: Prior to calibration meter was reading 90.4% oftest meter-Site meter read 41 .5 GPM and test meter read 45.9 GPM. Performed By: NP Conaway Date: 717/22 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications. Calibration was performed using standards and/or instrumentation whose accuracy is traceable to the N.I.S .T. Signature ~ PC CONTROLS I r--..:J C:::::: Location: City of Dania Beach WTP Function: East Influent Flowmeter Technician: NP Conaway P.C. Controls Inc 4114 W Palm Aire Dr 14 IB, Pompano Beach, FL 33069 Phone: (954) 568-9663; Fax: TBD E-mail: pccontrolsinc@bellsouth.net Cal. Type: Ultrasonic Comparison Date: 6/15/22 DueDate: 6/23 Interval: Yearly Test Equipment Used: Fuji Portaflow, Fluke 787 Mfr: Seametrics Full Scale: 1500 GPM Input 0 1222 Type: SCADA Measured Output (mA) (v) B A 4.00 17.10 4.00 17.0 01 Full Signal in Req . Output GPMIMGD Scale mNVolt 0 4 0 25 8 375 50 12 750 75 16 1125 100 20 1500 Transmitter Calibration Data Model#: FT500-22 Req 'd Output (mA) (v) 4.00 17.0 Remarks MA Receiver Calibration Data Full Scale: 1500 GPM Indication GPMIMGD 0 375 750 1125 1500 Remarks GPM Serial#: 07980639 Line Size: 16" DialX: I This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications. Calibration was performed using standards and/or instrumentation whose accuracy is traceable to the N.I.S.T. s;gnature : ~ P.C. Controls Inc PC CONTROLS 4114 W Palm Aire Dr l41B, Pompano Beach, FL 33069 Phone: (954) 568-9663 , Fax: TBD I ::r--.J" C::: E-mail: pccontrolsinc@bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit# 06-00187-W Test Site East Influent Flow Transmitter District ID# Contact Nate Costa Number 954 924-3616 Meter Model Seametrics FT440-W Serial# 1011805 Meter Accessories: None Pipe Information at test site Material Ductile Iron Schedule 53 Outside Diameter 17.4" OD Pipe Thickness 0.43" WT Transducer Spacing 13.52" V-Mount Distance from Meter installation is 20 feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ __ 1208 _____ GPM Initial Meter Reading at Calibration Start: 875200 X 1 End: 887200 -----x l __ 12,000 __ Gallons Totalized in _589 __ Seconds Average _1222.4_ GPM Test Meter Reading at Calibration Start : 0 x 1 ---End: 12000 X 1 __ 12,000 __ Gallons Totalized in _596 __ Seconds Average _1208.1_ GPM Meter Tested at _ l 01.2 _ % Accuracy Last Meter Test N I A Last Accuracy __ _ Comments: Prior to calibration meter was reading 101.2% of test meter -Site meter read 1222.4 GPM and test meter read 1208. l GPM. Performed By: NP Conaway Date: 6115 /22 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications . Calibration was performed using standards and /or instru tation whose accuracy is traceable to the N.l.S .T. Signature PC P.C. Controls Inc CONTROLS 4114 W Palm Aire Dr 14 IB, Pompano Beach, FL 33069 Phone: (954) 568-9663; Fax: TBD I r--..T C::. E-mail: pccontrolsinc@bellsouth.net Location: City of Dania Beach WTP Function: Influent to Membranes tlowmeter, FIT-1020 Technician: NP Conaway Cal. Type: Ultrasonic Comparison Date: 6/15/22 DueDate: 6/23 Interval: Yearly Test Equipment Used: FUJI Portraflow, Fluke 787, Hart 475 Mfr: Rosemount Full Scale: 2000 GPM Input 771 771 4.00 mA 20 .00mA Type: SCADA Measured Output (mA) (v) B A 771 771 10.16 10 .16 4.00 4.00 20.00 20.00 01 Full Signal in Req. Output GPM/MGD Scale mANolt 0 4 0 50 12 1000 100 20 2000 Transmitter Calibration Data Model#: 8750WA Req 'd Output (mA) (v) Remarks Serial#: 0011439 Line Size: 1 O" 771 AVG.GPM 10 .16 mA 4.00 20.00 Receiver Calibration Data Full Scale: 2000 GPM Indication GPM/MGD 0 1000 2000 Remarks GPM Dial X: 1 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications. Calibration was performed using stand~~mentation whose accuracy is traceable to the N .I.S.T. Signature : ~' - PC CONTROLS II:-...J"~ P.C . Controls Inc 4114 W Palm Aire Dr 141 B, Pompano Beach , FL 33069 Phone: (954) 568-9663 , Fax: TBD E-mail : pccontrolsinc @bellsouth .net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit # 06-00187-W Test Site Influent to Membranes Flow transmitter, FIT-1929 District ID #_ Contact Nate Costa Number 954 924-3616 Meter Model Rosemount 8750W A Serial # 0011439 Meter Accessories: Mag Pipe Information at test site Material Outside Diameter .11.J..'..'. 0 D Pipe Thickness 1.0" WT Transducer Spacing 7.737" V-Mount Distance from Meter installation is 5 feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @_754 ______ GPM Initial Meter Reading at Calibration Start: 39585200 X 1 End: 39585904 X I --------- __ 7,904 __ Gallons Totalized in _615 __ Seconds Average _771 .1_ GPM Test Meter Reading at Calibration Start: __ O __ X_l _ End: __ 8000 __ X_l __ 8,000 __ Gallons Totalized in _636 __ Seconds Average _754.l _ GPM Meter Tested at _ l 02.3 _ % Accuracy Last Meter Test 6/21 Last Accuracy_99 .9%_ Comments: Prior to calibration meter was reading 102.3% of test meter -Site meter read 771 . l GPM and test meter read 754 . l GPM. Performed By: NP Conaway Date: 6/15 /22 This is to certify that th e above li sted equipment has been calibrated and meets or exceeds all publi shed specifi cation s. Calibration was performed usi ng standards and/or instru tion whose accuracy is traceable to the N .I.S .T. Signature P.C. Controls Inc PC CONTROLS 4114 W Palm Aire Dr 141B, Pompano Beach, FL 33069 Phone: (954) 568-9663; Fax: TBD :c:r:....:rc::::: E-mail: pccontrolsinc@bellsouth.net Location: City of Dania Beach WTP Function: RO Train 1 Concentrate flowmeter Technician: NP Conaway Test Equipment Used: FUJI Portaflow, Fluke 787, Hart 475 Cal. Type: Ultrasonic Comparison Date: 717/22 DueDate: 6/23 Interval: Yearly Mfr: Rosemount Transmitter Calibration Data Model#: 8750WA Serial#: 0010681 Line Size: 8" Full Scale: 150 GPM Input 0 0 4.00mA 20.00 mA Type: SCADA Measured Output (mA) (v) B A 0 0 4.00 4.00 4.00 4.00 20.02 20.00 01 Full Signal in Req. Output GPM/MGD Scale mA/Volt 0 4 0 50 12 75 100 20 150 Req 'd Output (mA) (v) Remarks 0 AVG.GPM 4.00 mA 4.00 20.00 Receiver Calibration Data Full Scale: 150 GPM Indication GPM/MGD 0 75 150 Remarks GPM Dial X: 1 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications. Calibration w~ P'<fnrmOO o<ing <tand"d; ~df~ntatfon who~ ~'uracy i• •~eoblo to tho N .I.S.T. Signature : ~ PC CONTROLS I J:"-..J" C:::: P.C . Controls Inc 4114 W Palm Aire Dr 141B, Pompano Beach, FL 33069 Phone: (954) 568-9663, Fax: TBD E-mail: pccontrolsinc@ bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit # 06-00187-W Test Site Train I Concentrate Flow transmitter, FIT-3165 District ID# Contact Nate Costa Number 954 924-3616 Meter Model Rosemount 8750W Serial# 0010681 Meter Accessories: Mag Pipe Information at test site Material Stainless Steel Schedule 10 Outside Diameter 3 .50" OD Pipe Thickness 0.120" WT Transducer Spacing 5 .72" V-Mount Distance from Meter installation is 20 Feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ __ 76.2 _____ GPM Initial Meter Reading at Calibration Start: 101 791500 X 1 End: 101792289 x 1 ------- 789 Gallons Totalized in 615 Seconds ------Average _77.0_ GPM Test Meter Reading at Calibration Start: 0 X 1 End : ------785 x 1 785 Gallons Totalized in 618 ---Seconds Average _ 76.2_ GPM Meter Tested at _101.0_ % Accuracy Last Meter Test 6/21 Last Accuracy_96.6%_ Comments: Prior to calibration meter was reading 101% oftest meter -Site meter read 77.0 GPM and test meter read 76.2 GPM. Performed By: NP Conaway Date: 7 /7 /22 This is to certi fy that the above li sted equipment has been calibrated and meets or exceeds all published specifications . Calibration was performed using standards and/or instru ation whose accuracy is traceable to the N .I.S .T. Signature PC P.C . Controls Inc CONTROLS 4114 W Palm Aire Dr 141B , Pompano Beach, FL 33069 Phone: (954) 568-9663; Fax : TBD Ir.....:JC:: E-mail: pccontrolsinc@ bellsouth.net Location: City of Dania Beach WTP Function : RO Train 2 Concentrate tlowmeter, FIT-3265 Technician: NP Conaway Cal. Type: Ultrasonic Comparison Date: 717/22 DueDate: 6/23 Interval: Yearly Test Equipment Used: FUJI Portaflow, Fluke 787, Hart 475 Mfr: Rosemount Full Scale: 150 GPM Input 76.2 76.2 4.00 mA 20.00 mA Type: SCADA Measured Output (mA) (v) B A 76.2 76.2 12.12 12.12 4.00 4.00 20.00 20.00 01 Full Signal in Req. Output GPM/MGD Scale mANolt 0 4 0 50 12 75 100 20 150 Transmitter Calibration Data Model#: 8750WA Req 'd Output (mA) (v) Remark s Serial#: 0010682 Line Size : 8" 76.2 AVG.GPM 12.12 mA 4.00 20.00 Receiver Calibration Data Full Scale: 150 GPM Indication GPM/MGD 0 75 150 Remarks GPM Dial X: 1 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published s pecifications . Calibration was performed using standards an7entation whose accuracy is traceable to the N.I.S.T. Signature : ~ PC CONTROLS J: r--..J" c::::: P.C. Controls Inc 4114 W Palm Aire Dr 14 lB, Pompano Beach, FL 33069 Phone: (954) 568-9663, Fax: TBD E-mail: pccontrolsinc@bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit# 06-00187-W Test Site Train 2 Concentrate Flow transmitter, FTT-3265 District ID# Contact Nate Costa Number 954 924-3616 Meter Model Rosemount 8750W A Serial# 0010682 Meter Accessories: Mag Pipe Information at test site Material PVC Schedule 80 Outside Diameter 8.625" OD Pipe Thickness 0.5'' WT Transducer Spacing 5.72" V-Mount Distance from Meter installation is 20 Feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ _76.2 ______ GPM Initial Meter Reading at Calibration Start: _7802912_X _l_ End: _7803712 __ X_J __ 800 ___ Gallons Totalized in _ 622 __ Seconds Average _ 77.2_ GPM Test Meter Reading at Calibration Start : 0 X 1 End: 800 X 1 ------- 800 Gallons Totalized in 630 ----Seconds Average _ 76.2_ GPM Meter Tested at _101.3_ % Accuracy Last Meter Test 6/21 Last Accuracy_lOl .3%_ Comments: Prior to calibration meter was reading 101.3% oftest meter-Site meter read 77.2 GPM and test meter read 76.2 GPM. Performed By: NP Conaway Date: 717/22 This is to certify that the above li sted equipment has been calibrated and meets or exceeds all published specifications. C"1 ibratio::::rm<d u•ing '"°'7trum~brtiou who" •reuraoy fa trare•hl< to the N.L.S .T. P.C. Controls Inc PC CONTROLS 4114 W Palm Aire Dr 141B, Pompano Beach, FL 33069 Phone: (954) 568-9663 ; Fax: TBD I r--..J C:::: E-mail: pccontrolsinc@bellsouth.net Location: City of Dania Beach WTP Function: High Service Effluent Flow Transmitter Technician: NP Conaway Cal. Type: Pressure Date: 717 122 DueDate: 6/23 Interval: Yearly Test Equipment Used: Fluke 717, Fluke 787 Transmitter Calibration Data Mfr: ABB Model#: 264DSGSSB I H Full Scale: 6000 GPM@ 107.56" H20 Measured Req 'd Output Input Output (mA) (v) (mA) (v) B A Remarks O" 4.02 53.78" 15.33 107.56" 20.02 4.00 mA 4.00 20.00mA 20.00 Type: SCADA 01 Full Signal in Scale mA/Volt 0 4 25 8 50 12 75 16 100 20 4.00 15.31 20.00 4.00 20.00 Req . Output GPM/MGD 0.0 1500.0 3000.0 4500.0 6000.0 4.00 MA 15.31 20.00 4.00 20.000 Receiver Calibration Data Full Scale: 6000 GPM Indication GPM/MGD 0.5 1500.3 3000.2 4500.2 6000.4 Remarks GPM Serial#: 6407008756 Line Size: DialX: 1 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published s pecifications. Calibration was performed using standards and/or i mentation whose accuracy is traceable to the N .l.S .T. Signature P.C. Controls Inc PC CONTROLS 4114 W Palm Aire Dr 141 B , Pompano Beach, FL 33069 Phone: (954) 568-9663; Fax: TBD :c::r:---..:rc:::: E-mail: pccontrolsinc@ bellsouth.net Location: City of Dania Beach WTP Function: High Service Effluent Pressure Transmitter Technician: NP Conaway Cal. Type: Pressure Date: 7 /7 /22 DueDate: 6 /23 Interval: Yearly Test Equipment Used: Fluke 717, Fluke 787 Mfr: ABB Full Scale: 348 PSI lnput 0 87 174 361 348 Type: SCADA Measured Output (mA) (v) B A 4.01 8.00 12.00 16.00 - 4.00 8.00 12.00 16.00 - 01 Full Signal in Req . Output GPM/MGD Scale mAfVolt 0 4 0.0 25 8 87.0 50 12 174.0 75 16 261.0 100 20 348.0 Transmitter Calibration Data Model#: 2600T Req 'd Output (mA) (v) 4.00 8.00 12.00 16.00 20.00 Remarks Receiver Calibration Data Full Scale: 348 PSI Indication GPM/MGD 0.0 87.0 174.0 261.0 348.0 Remarks PSI Serial#: 6407008757 Line Size: DialX: I This is to certify that the above listed equipment has been calibrated and meets or exceeds all publi shed specifications. Calibration was performed using standards and/or inst ntation whose accuracy is traceable to the N .I.S .T. Signature