Loading...
HomeMy WebLinkAboutInv# PCI221577 - PC CONTROLS, INC - 06/27/2023Invoice Date 6/27/2023 Invoice # PCI221577 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Water Treatment Plant Nate Costa PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 230157 Terms Net 30 Due Date 7/27/2023 Technician PC/DE Comments Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Hours - Contract 2... Technician5 67.00 335.006/22/2023 Delivered to site three (3) FT440 flowmeter head replacements. Install 1 new FT440 on East Supernate flowmeter. Program, calibrate and certify. Troubleshoot proximity switch for Slaker feed belt. Clean switch and belt feed wheel - Indicator goes Off and On but proximity switch contacts don't open and close. Proximity switch needs replaced. Xmtr Fee - Contract Transmitter Certification Fee1 49.00 49.00 Fuel Surcharge - ... Broward and other1 10.00 10.00 $394.00 $394.00 $0.00 PC CONTROLS Ir--.JC::, P.C. Controls Inc 4 t 14 W Palm Aire Dr 141 B , Pompano Beach, FL 33069 Phone: (954) 568-9663 , Fax: TBD E-mail: pccontrolsinc@ bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit # 06-00187-W Test Site East Supernatent Flow Transmitter, FIT-123 District ID# ___ _ Contact Nate Costa Number 954 924-3616 Meter Model Seametrics FT440E Serial# 06230382 Meter Accessories: None Pipe Information at test site Material PVC Schedule 40 Outside Diameter 2.375" OD Pipe Thickness .154" WT Transducer Spacing 0 .55" Z-Mount Distance from Meter installation is 10 feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ __ 47.2 ______ GPM Initial Meter Reading at Calibration Start: 0 XI ---End: 400 X 1 ---- 400 Gallons Totalized in 505 Seconds Average_ 4 7 .5_ GPM ---- Test Meter Reading at Calibration Start: 0 X I ---End : 400 X 1 ---- 400 ____ Galtons Totalized in 508 Seconds Average _ 47.2_ GPM Meter Tested at _100.6_ % Accuracy Last Meter Test 7 /22 Last Accuracy_l00.4%_ Comments : New Meter replacement haed. Prior to calibration meter was reading 100.6% of test meter - Site meter read 47.5 GPM and test meter read 47.2 GPM. Performed By: NP Conaway Date: 6 /22/23 Thi s is to certify that the above li sted equipment has been calibrated and me ets or exceed s all published specification s. Calibration was performed using standards and /or instrumentation who se accurac y is traceable to the N.l.S .T . Signature