Loading...
HomeMy WebLinkAboutInv# PCI221599 - PC CONTROLS, INC - 07/19/2023Invoice Date 7/19/2023 Invoice # PCI221599 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Darren Green Maintenance - Lift stations PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 230157 Terms Net 30 Due Date 8/18/2023 Technician PC/DE Comments PC/MJ Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Hours - Contract Technician3 69.00 207.007/17/2023 Hours2 - Contract Technician 23 35.00 105.00 Troubleshoot Lead, Lag, and OFF floats at "IT Park" Liftstation and found that the OFF float was defective and needs to be replaced. To return tomorrow with float. Hours - Contract Technician7 69.00 483.007/18/2023 Hours2 - Contract Technician 27 35.00 245.00 Page 1 Invoice Date 7/19/2023 Invoice # PCI221599 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Darren Green Maintenance - Lift stations PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 230157 Terms Net 30 Due Date 8/18/2023 Technician PC/DE Comments PC/MJ Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Visited Liftstation 11 - operations state that it occasionally does not turn off. On arrival level was 2.9 feet so it had recently pumped and turned off. Wait for level to reach 3.5 observe Station coming on and shutting off at set point 2.1. Visit Liftstation #9 - operations state that pump occasionally does not shut off. On arrival station had a fault for phase failure, reset fault and wait for level to rise to bring pump on as water began to rise we see that we have a backup activated light before pump comes on we see that station has been running on back up probe rather than submersible level transmitter. Remove backup probe from Wet Well and clean - adjust level of backup probe so that it will be activated after Lead pump set point. Now system will run on submersible level transmitter - diagnosis pump most likely kept running because of dirty backup probe. Visit IT Park Liftstation and replace OFF float (customer provided - test flow sequence and put into service. Return to Liftstation 11 - upon arrival level was at 2.9 wait for water to rise to ON set point of 3.5 - pumped down and shut off at OFF set point 2.1 station has been working correctly all day. Lot Material - misc1 5.00 5.00 Page 2 Invoice Date 7/19/2023 Invoice # PCI221599 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Darren Green Maintenance - Lift stations PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 230157 Terms Net 30 Due Date 8/18/2023 Technician PC/DE Comments PC/MJ Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Fuel Surcharge - ... Broward and other2 10.00 20.00 Page 3 $1,065.00 $1,065.00 $0.00