Loading...
HomeMy WebLinkAboutInv# PCI221834 - PC CONTROLS, INC - 04/09/2024Invoice Date 4/9/2024 Invoice # PCI221834 Bill To City of Dania Beach Accounts Payable 100 West Dania Beach Blvd Dania Beach, FL 33004 Service Location Water Treatment Plant Nate Costa PC Controls Inc 4114 W. Palm Aire Drive #141B Pompano Beach, FL 33069 P.O. Number 2024-00000010 Terms Net 30 Due Date 5/9/2024 Technician PC Comments Accounts not paid within 30 days of the date of the invoice are subject to a 1.5% finance charge. Phone # (954) 568-9663 Fax # TBD pccontrolsinc@bellsouth.net Total Due Subtotal Sales Tax (0.0%) Unit DescriptionQuantity Price Each AmountService Date Hours - Contract Technician4 69.00 276.004/8/2024 Clean, calibrate and certify West Influent flowmeter and West Supernate flowmeter. Xmtr Fee - Contract Transmitter Certification Fee2 49.00 98.00 Fuel Surcharge - ... Broward and other1 10.00 10.00 $384.00 $384.00 $0.00 P .C. Controls Inc PC CONTROLS 4114 W Palm Aire Dr 14 IB , Pompano Beach, FL 33069 Phone : (954) 568-9663, Fax: TBD J: r--..:r c::: E-mail: pccontrolsinc @ bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit # 06-00187-W Test Site West Influent Flow Transmitter District ID# Contact Nate Costa Number 954 924-3616 Meter Model Seametrics FT440W Serial # 06201036 Meter Accessories: None Pipe Information at test site Material Ductile Iron Outside Diameter 13 .2" OD Pipe Thickness .4" WT Transducer Spacing 9.99" V-Mount Distance from Meter installation is Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test perfonned @ __ 1250.0 ____ GPM Initial Meter Reading at Calibration Start: 740000 X 1 End : 752000 x 1 _12 ,000 __ Gallons Totalized in _574 __ Seconds Average _1254.4_ GPM Test Meter Reading at Calibration Start: 0 X I End : 12000 __ X _I _ 12,000 __ Gallons Totalized in _ 600 __ Seconds Average _1250 .0_ GPM Meter Tested at _99.6_ % Accuracy Last Meter Test N I A Last Accuracy __ _ Comments: Prior to calibration meter was reading 99.6% oftest meter -Site meter read 1254.4 GPM and test meter read 1250.0 GPM. Performed By: NP Conaway Date: 4/8/24 Thi s is to certify that the above li sted equipment has been c ibrated and mee ts or exceeds all publi shed s pecification s. Calibration was performed using standard s and/or in st entation who se accuracy is traceabl e to the N .l.S.T. Signature PC CONTROLS J: r--..:r c:::: P.C. Controls Inc 4114 W Palm Aire Dr 14 IB, Pompano Beach, FL 33069 Phone: (954) 568-9663, Fax: TBD E-mail: pccontrolsinc@bellsouth.net Certified Flow Meter Test Record Customer: City of Dania Beach Consumptive Use Permit# 06-00187-W Test Site West Supematent Flow Transmitter, FIT-103 District ID# ___ _ Contact Nate Costa Number 954 924-3616 Meter Model Seametrics FT440W Serial# 042017000073 Meter Accessories: None Pipe Information at test site Material PVC Schedule 40 Outside Diameter 2.375" OD Pipe Thickness .154" WT Transducer Spacing 0 .55" V-Mount Distance from Meter installation is 3 feet Test Information using Fuji Porta-Flow Portable Ultrasonic Flowmeter Test performed @ __ 26.2 _____ GPM lnitial Meter Reading at Calibration Start: 2005 X 1 End: 2305 X I ------ 300 Gallons Totalized in 679 Seconds ---Average _ 26 .5_ GPM Test Meter Reading at Calibration Start: 0 Xl ---End: 300 X I --- 300 Gallons Totalized in 688 Seconds ---Average _26.2_ GPM Meter Tested at _I 00.l_ % Accuracy Last Meter Test N I A ---Last Accuracy __ _ Comments: Prior to calibration meter was reading 10 I . I% of test meter -Site meter read 26.5 GPM and test meter read 26.2 GPM. Performed By: NP Conaway Date: 4/8/24 This is to certify that the above listed equipment has been calibrated and meets or exceeds all published specifications. Calibration was performed using standards and/or instrumentation w ose accuracy is traceable to the N.l.S.T. Signature